SPD 1 Module 1P+N 40kA (No MCB Required)
Enlarge
939480939481947241

SPD 1 Module 1P+N 40kA (No MCB Required)

Product Code: SPD401M

  • All In One Design - Does Not Require MCB
  • BS EN 61643-11 compliant
  • L-N is 2.5mm2, Torque is 1.2Nm.
  • Meets 18th Edition IET Wiring Regulations Amendment 2 requirements Transient Overvoltage Protection - 443.4.1
  • N-PE is 4mm2, Torque is 2.0Nm.
  • Type 2, Single phase, double pole, suitable for TN-S, TN-C-S and TT Earthing
Meets 18th Edition IET Wiring Regulations Amendment 2 requirements - Transient Overvoltage Protection - 443.4.1 SPDs In All Installations Overvoltage protection devices (SPDs) are now required in all installations however, in some cases the owner can opt out and accept all risks from such overvoltage's. The CED Axiom Double Pole 1 MOD S/P DEICE SPD 40KA 1P+N+PE is designed to give protection for fatal electric surge by reducing to “safe” levels the value. It also protect household and commercial distribution systems. This units disconnects both line and neutral going feeds on trip with 30mA tripping current. Single module deice not only saes space but also simplifies the installation process. Single module - No backup MCB required Busbar connected, DIN rail mount 275AC max. continuous, 100A rated Type 2, Single phase, double pole, suitable for TN-S, TN-C-S and TT Earthing Status indication and volt free contact for remote monitoring BS EN 61643-11 compliant

Product Summary

Meets 18th Edition IET Wiring Regulations Amendment 2 requirements - Transient Overvoltage Protection - 443.4.1 SPDs In All Installations Overvoltage protection devices (SPDs) are now required in all installations however, in some cases the owner can opt out and accept all risks from such overvoltage's. The CED Axiom Double Pole 1 MOD S/P DEICE SPD 40KA 1P+N+PE is designed to give protection for fatal electric surge by reducing to “safe” levels the value. It also protect household and commercial distribution systems. This units disconnects both line and neutral going feeds on trip with 30mA tripping current. Single module deice not only saes space but also simplifies the installation process. Single module - No backup MCB required Busbar connected, DIN rail mount 275AC max. continuous, 100A rated Type 2, Single phase, double pole, suitable for TN-S, TN-C-S and TT Earthing Status indication and volt free contact for remote monitoring BS EN 61643-11 compliant

Technical Specification

General Information
Applications Surge Protection For CED/AXIOM Consumer Units
Approvals/Certifications CE, UKCA
Barcode 5027825979514
Body material Nylon PA66
Dimensions (mm) 81*18*68.5
Frequency (Hz) 50/60
Input Voltage (Hz) 220-240
Phase 1
Poles 1P+N, single phase
Product Colour/Finish White
Terminal Capacity (mm²) LN 1.2Nm. PE 2.0Nm
Torque (Nm) LN 1.2Nm. PE 2.0Nm
Type SPD Type 2
Warranty Period (Years) 3
Weight (g) 123

Related Products



Earth Sleeving 3mm Green / Yellow
Product Code: S3GY
profix
Circuit Breaker 32A Sp B-Type
Product Code: CUB32SP
axiom
Oil Filled Radiator 2000W with Thermostat
Product Code: CR2
airmaster
Connector Box for Lighting + 3P Connector
Product Code: LCBOX
profix
PVC Sleeving 4mm Brown
Product Code: S4BRO
profix
Socket Screw M3.5 x 30mm Nickel Plated
Product Code: S3530NP
profix
Consumer Unit Gland Kit 32/25mm Nylon
Product Code: CUGK32/25NYL
axiom
Product Code: FFSMD5CW/PK50
meridian

Your basket is empty